DIESEL POWER-PLANT INSTALLATION

LOCATION QuantityCapacity

Engine Brand – Type

First

Operate

CLIENT OWNER
1 PLTD Tanjung Enim

Bukit Asam

4 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1985 CCM SULZER PT. PLN (Persero)

Wilayah IV

2 PLTD Tarahan

Bandar Lampung

2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1985 CCM SULZER PT. PLN (Persero)

Wilayah IV

3 PLTD Siantan

Pontianak

2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1986 CCM SULZER PT. PLN (Persero)

Wilayah V

4 PLTD Tanjung Karang

Lombok

3 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1987 CCM SULZER PT. PLN (Persero)

Wilayah XI

5 PLTD Tarahan

Bandar Lampung

1 Unit x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1987 CCM SULZER PT. PLN (Persero)

Wilayah IV

6 PLTD Teluk Betung Lampung 2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1987 CCM SULZER PT. PLN (Persero)

Wilayah IV

7 PLTD Langsa Lama

Langsa

2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1987 CCM SULZER PT. PLN (Persero)

Wilayah I

8 PLTD Lueng Bata

Banda Aceh

5 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1987 CCM SULZER PT. PLN (Persero)

Wilayah I

9 PLTD Simpang Haru Padang 2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1988 CCM SULZER PT. PLN (Persero)

Wilayah III

10 PLTD Teluk Lembu

Pekanbaru

5 Unit x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1988 CCM SULZER PT. PLN (Persero)

Wilayah III

11 PLTD Teluk Lembu

Pekanbaru

1 Unit x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1990 CCM SULZER PT. PLN (Persero)

Wilayah III

12 PLTD Trisakti

Banjarmasin

2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1990 CCM SULZER PT. PLN (Persero)

Wilayah VI

13 PLTD Sei Kledang

Samarinda

1 Unit x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1990 CCM SULZER PT. PLN (Persero)

Wilayah VI

14 PLTD Sei Kledang

Samarinda

2 Units x 6,3 mW

SULZER diesel 12 ZV 40/48

M/E Services

1991 CCM SULZER PT. PLN (Persero)

Wilayah VI

15 PLTD Silae

Palu

2 Units x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1992 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah VII

16 PLTD Karang Asam

Samarinda

2 Units x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1993 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah VI

17 PLTD Sei Raya

Pontianak

2 Unit x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1993 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah V

18 PLTD Teluk Lembu

Pekanbaru

2 Units x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1993 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah III

19 PLTD Ampenan

Lombok

2 Units x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1994 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah XI

20 PLTD Ampenan

Lombok

2 Units x 7,6 mW

SULZER diesel 12 ZAV 40S

M/E Services

1995 New Sulzer Diesel

France (NSDF)

PT. PLN (Persero)

Wilayah XI

21 PLTG Tello

Ujung Pandang

2 Units x 30-40 mW gas engine

General Electric GT

Joint Operation (J/O)

1998 PT. PLN (Persero)

Wilayah VIII

PT. PLN (Persero)

Wilayah VIII

22 PLTD Payo Selincah

Jambi

6 Units x 2,5 mW

SACM Diesel 12 V 200

M/E Services

1998 PT. Stowindo Power

M/E Services

PT. PLN (Persero)

Wilayah IV

23 PT. Krakatau Wajatama

Cilegon

1 Unit x 100 kVA

PERKINS

Supply & Erect

1998 PT. Krakatau

Wajatama

PT. Krakatau

Wajatama

24 PT. Apac Inti Corpora

Bawen, Semarang

1 Unit x 400 kVA

VOLVO Penta HPV 1630TWD

Supply & Erect

1998 NSD Singapore

Pte., Ltd.

PT. Vitadaya

Harapan (VDH)

25 PT. Apac Inti Corpora

Bawen, Semarang

5 Units x 11 mW

SULZER diesel 16 ZAV 40S

M/E Services

1998 NSD Singapore

Pte., Ltd.

PT. Vitadaya

Harapan (VDH)

26 PLTD Kendari

Sulawesi Tenggara

2 Units x 2,8 mW

Mirless Blackstone

M/E Services

1998 PT. Mirlindo Padu Kencana PT. PLN (Persero)
27 PLTD Pesanggaran Denpasar – Bali Installation of MFO Fuel System Supply & Erection 2009 PT. Indonesia Power UBP – Bali PT Indonesia Power UBP – Bali
28 PLTD BUGAK Konsorsium

Ampenan – Lombok

5 Units x 9.76 mW

SULZER diesel 14 ZAV 40S

M/E Services

Under Construct PT. PLN (Persero) Wilayah NTB PT Bangun Panca Sarana Abadi
29 PLTD Jeranjang Konsorsium Installation of MFO Fuel System Supply & Erection 2014 PT. PLN (Persero) Wilayah NTB PT Bangun Panca Sarana Abadi
30 PLTD Paokmotong – Mataram – Lombok Installation of MFO Fuel System Supply & Erection 2016 PT. PLN (Persero) Wilayah NTB Sektor Pembangkitan Lombok PT. PLN (Persero) Wilayah NTB Sektor Pembangkitan Lombok
31 PLTD Sumbawa

Sumbawa, NTT

3 Unit x 10.5 mW

SULZER diesel 16 ZAV 40S

M/E Services & Overhaul

2017 PT. PLN (Persero) Wilayah NTB PT Sumber Rezeki Power
32 PLTD Pringgabaya – Mataram – Lombok Installation of MFO Fuel System Supply & Erection 2017 PT. PLN (Persero) Wilayah NTB Sektor Pembangkitan Lombok PT. Iradat Aman
33 PLTD Ampenan – Lombok Installation Air Filter 2017 PT. PLN (Persero) Wilayah NTB Sektor Pembangkitan Lombok PT. PLN (Persero) Wilayah NTB Sektor Pembangkitan Lombok